Chapter 2
6) Fit the drum fixing member [1].
- 1 screw [2]
[2]
7) Tighten the 2 process joint shafts [1] and the ITB joint shaft [2].
- Hold the drum fixing member [3] steady when tightening the shaft of the
ITB joint shaft [2].
- If the drum fixing member is not held steady, the shaft [2] will rotate
without tightening.
[1]
[2]
8) Connect the connector [1] and other 7 connectors [2].
2-48
[1]
F-2-115
[1]
F-2-116
[3]
F-2-117
[1]
9) Connect the 6 connectors [1], and fix it in place with the cable guide [2]
and the clamp [3].
[1]
10) Remove the A3 paper[1].
[1]
11) Shift down the lock lever [1] in the direction of the arrow to release.
[1]
12) Hold it tight with both hands, and move the hopper assembly [1] down
slowly in the direction of the arrow.
[2]
F-2-118
[1]
[2]
[3]
F-2-119
F-2-120
F-2-121