Subheading
OFST-P-Y/M/C/K
OFSTPLM
OFSTPLC
OFSTP2Y
OFSTP2M
OFSTP2C
OFSTP2K
OFSTP2LM
OFSTP2LC
OFSTP3Y
OFSTP3M
OFSTP3C
OFSTP3K
OFSTP3LM
OFSTP3LC
9. COLOR
COPIER > ADJUST > PASCAL
Adjust the offset for the test print reading signal (Y/M/C/K color) at PASCAL control for
automatic gradation correction (full correction).
Adjustment method
- When you set a larger value, the image density after automatic gradation correction (full
correction) becomes darker.
Adjustment range: -128 to +128
Standard value: 0
Not used
Not used
Adjust the density at test print reading
Keep the Y density adjustment value when test print reading was performed (Media 2)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Adjust the density at test print reading
Keep the M density adjustment value when test print reading was performed (Media 2)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Adjust the density at test print reading
Keep the C density adjustment value when test print reading was performed (Media 2)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Adjust the density at test print reading
Keep the K density adjustment value when test print reading was performed (Media 2)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Not used
Not used
Adjust the density at test print reading
Keep the Y density adjustment value when test print reading was performed (Media 3)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Adjust the density at test print reading
Keep the M density adjustment value when test print reading was performed (Media 3)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Adjust the density at test print reading
Keep the C density adjustment value when test print reading was performed (Media 3)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Adjust the density at test print reading
Keep the K density adjustment value when test print reading was performed (Media 3)
Adjustment range: -128 to +128
Standard value: 0
When replacing the reader controller, input the value written on the service label once again.
Not used
Not used
T-16-110