Subheading
CS1OFHIY
CS2OFDMK
CS2OFDMC
CS2OFDIK
CS2OFDIC
CS2OFHMK
CS2OFHMC
CS2OFHIK
CS2OFHIC
CS2OFWMK
CS2OFWMC
CS2OFWIK
CS2OFWIC
CS1OFWMM
CS1OFWIY
16.4.2 FEEDER
16.4.2.1 FEEDER List
imagePRESS C1 / imagePRESS C1+
Subheading
DOCST
COPIER > ADJUST > P-PASCAL
Adjust the main unit offset of the HT ideal brightness value Y for Color Sensor 1.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid actual measurement brightness value K for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid actual measurement brightness value C for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid ideal brightness value K for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid ideal brightness value C for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the HT actual measurement brightness value K for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the HT actual measurement brightness value C for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the HT ideal brightness value K for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the HT ideal brightness value C for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid white actual measurement brightness value K for Color
Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid white actual measurement brightness value C for Color
Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid white ideal brightness value K for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid white ideal brightness value C for Color Sensor 2.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid white actual measurement brightness value M for Color
Sensor 1.
Setting range: 0 to 1023
Standard value: 0
Adjust the main unit offset of the solid white ideal brightness value Y for Color Sensor
Setting range: 0 to 1023
Standard value: 0
Adjust the position of the lead edge of a document image.
Adjustment method
When you increase the setting value, the lead edge timing becomes slow.
Adjustment range
-7 to +7 (Unit: 0.5mm)
Contents
T-16-119
FEEDER>ADJSUT
Contents
Chapter 16
Level
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0011-9642
Level
1
16-115