4) Remove the primary corona assembly. (page 7-86)Reference [Remov-
ing the Primary Corona Assembly]
5) Remove the pre-transfer corona assembly. (page 7-88)Reference [Re-
moving the pre-transfer corona assembly]
6) Detach the drum unit. (page 7-89)Reference [Removing the Drum Unit]
7) Detach the drum cleaning blade. (page 7-93)Reference [Removing the
Drum Cleaning Blade]

7.14.17.2 Removing the End Seal (Rear)

imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
1) Remove the end seal (rear) [1].
- 1 screw [2]
7.14.18 Drum Cleaner Brush
7.14.18.1 Preparation for Removing the Drum Cleaner
Brush
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
1) Open the front cover.
2) Detach the process unit cover.
3) Hold up the hopper unit.
4) Remove the primary corona assembly. (page 7-86)Reference [Remov-
ing the Primary Corona Assembly]
5) Remove the pre-transfer corona assembly. (page 7-88)Reference [Re-
moving the pre-transfer corona assembly]
6) Detach the drum unit. (page 7-89)Reference [Removing the Drum Unit]
7) Detach the photosensitive drum. (page 7-90)Reference [Removing the
Photosensitive Drum]
8) Detach the drum cleaning pre-exposure LED unit. (page 7-86)Reference
[Removing the Drum Cleaning Pre-Exposure LED Unit]
9) Detach the scoop-up sheet support plate. (page 7-92)Reference [Remov-
ing the Scoop-Up Sheet Support Plate]
10) Detach the seal support plate (rear). (page 7-91)Reference [Removing
the Seal Support Plate (Rear)]
11) Detach the seal support plate (front). (page 7-91)Reference [Removing
the Seal Support Plate (Front)]
7.14.18.2 Removing the Drum Cleaner Brush
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
1) Remove the drum cleaner brush [1].
- 3 E-rings [2]
- 2 gears [3]
- 2 bearings [4]
- 2 sponges [5]
[5]
[4]
[3]
[2]
7.14.19 Photosensitive Drum Cleaning Blade
7.14.19.1 Preparation for Removing the Drum Cleaning
Blade
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
[1]
[2]
F-7-157
[5]
[1]
[2]
[3]
[2]
[4]
F-7-158
1) Open the front cover.
2) Detach the process unit cover.
3) Hold up the hopper unit.
4) Remove the primary corona assembly. (page 7-86)Reference [Remov-
ing the Primary Corona Assembly]
5) Remove the pre-transfer corona assembly. (page 7-88)Reference [Re-
moving the pre-transfer corona assembly]
6) Detach the drum unit. (page 7-89)Reference [Removing the Drum Unit]
0013-9744
7.14.19.2 Removing the Drum Cleaning Blade
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
1) Remove the drum cleaner cover [1].
- 1 wire saddle [2] (Remove the harness)
- 1 connector [3]
- 5 screws [4]
0013-9757
2) Detach the drum cleaning blade unit [1].
- 1 E-ring [2]
- 1 leaf spring [3]
3) Detach the drum cleaning blade [1].
0013-9758
- 3 screws [2]
7.14.20 Hopper Assembly
7.14.20.1 Preparation for Removing the Sub Hopper Unit
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
1) Open the front cover.
2) Open the toner replacement cover.
7.14.20.2 Removing the Sub Hopper Unit
imagePRESS C1 P / imagePRESS C1
The sub hopper for Cyan is explained here as the example. The procedure is
same for other colors.
1) Detach the hopper left cover [1].
0013-9739
- 1 screw [2]
[4]
[4]
[1]
[4]
[2]
[3]
F-7-159
[2]
[3]
[1]
F-7-160
[2]
[1]
F-7-161
Chapter 7
0013-9740
0014-1295
0014-1296
7-93