Canon imagePRESS C1 P Service Manual page 994

Imagepress c1 series
Table of Contents

Advertisement

Subheading
TR-CLR1 to 8
Color mode setting items for the secondary transfer ATVC setting
1: Bk mode, 2: C mode
[Factory setting value / Value after RAM clear: 1]
Reference:
6 items of 2TR-TGT, 2TR-SHR, TR-PPR, TR-ENV, TR-CLR, and TR-DUP are treated as one
set.
TR-DUP1 to 8
Single or double-sided paper mode setting items for the secondary transfer ATVC setting
Setting range: 1 to 4
1: Single sided, 2: Automatic double sided, 3: Manual feed double sided, 4: POD deck
[Factory setting value / Value after RAM clear: 1]
Reference:
6 items of 2TR-TGT, 2TR-SHR, TR-PPR, TR-ENV, TR-CLR, and TR-DUP are treated as one
set.
1TR-TGY/M/C
Adjust the target current offset for the primary transfer ATVC. (Y/M/C)
Adjustment range: -10 - 10 (Unit: 1.0µA)
[Factory setting value / Value after RAM clear: 0]
1TR-TGK1
Adjust the target current offset for the primary transfer ATVC. (Bk: single color)
Adjustment range: -10 - 10 (Unit: 1.0µA)
[Factory setting value / Value after RAM clear: 0]
1TR-TGK4
Adjust the target current offset for the primary transfer ATVC. (Bk: 4C)
Adjustment range: -10 - 10 (Unit: 1.0µA)
[Factory setting value / Value after RAM clear: 0]
TR-INTVL
Adjust the primary transfer bias between color/paper interval.
Adjustment range
-16 to 16 (Unit: 5%)
Standard value
0
1EL
Set a ITB tension roller bias value.
After monitoring is performed to the bias value by DISPLAY<HV-STS<1EL, set a bias value
using this mode.
Setting range: -2000 to 0 (Unit: V)
[Factory setting value / Value after RAM clear: -1899]
2EL
Set a bias value of the secondary transfer static eliminator.
Adjustment method
After monitoring is performed to the bias value by DISPLAY<HV-STS<2EL, set a bias value
using this mode.
Setting range: -4000 to 0 (Unit: V)
[Factory setting value / Value after RAM clear: 0]
1TR-STS1
Offset value of the target current for the primary transfer paper interval (at constant speed)
Setting range: -10 to 10 (Unit: 5.0µA)
[Factory setting value / Value after RAM clear: 0]
1TR-STS3
Offset value of the target current for the primary transfer paper interval (at 1/3 speed)
Setting range: -10 to 10 (Unit: 5.0µA)
[Factory setting value / Value after RAM clear: 0]
PRE-TR-Y/M/C
Adjust the current of the pre-transfer charging assembly. (Y/M/C)
Set the current offset value (Y/M/C) of the pre-transfer charging assembly.
This is not used for this machine.
POSTSW-Y/M/C/K
ON/OFF switch for the Y/M/C/K pre-transfer charging assembly
Set validity or invalidity of Y/M/C/K color for the pre-transfer charging assembly.
Setting value
0: Invalid, 1: Valid
[Factory setting value / Value after RAM clear: Y/M/C:0, K:1]