Copier List - Canon imagePRESS C1 P Service Manual

Imagepress c1 series
Table of Contents

Advertisement

Subheading
SGNL-C-Y
SGNL-C-M
SGNL-C-K
SGNL-C-C
DLTA-A-Y
DLTA-A-M
DLTA-A-C
DLTA-A-K
DLTA-B-Y
DLTA-B-M
DLTA-B-C
DLTA-B-K
DLTA-C-Y
DLTA-C-M
DLTA-C-C
DLTA-C-K

16.2.1.3 COPIER List

imagePRESS C1+ (Printer) / imagePRESS C1+
COPIER<DISPLAY<HT-C
Latest patch result in each pattern of ARCDAT (Y in Screen C)
Setting range: 0 to 1023
Standard value: 0
Latest patch result in each pattern of ARCDAT (M in Screen C)
Setting range: 0 to 1023
Standard value: 0
Latest patch result in each pattern of ARCDAT (K in Screen C)
Setting range: 0 to 1023
Standard value: 0
Latest patch result in each pattern of ARCDAT (C in Screen C)
Setting range: 0 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (Y in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (M in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (C in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (K in
Screen A)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (Y in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (M in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (C in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (K in
Screen B)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (Y in
Screen C)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (M in
Screen C)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (C in
Screen C)
Setting range: -1023 to 1023
Standard value: 0
Difference between the latest patch result and the target value in each pattern of ARCDAT (K in
Screen C)
Setting range: -1023 to 1023
Standard value: 0
Contents
Chapter 16
Level
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0020-6571
16-33

Hide quick links: