1. Hold the drum fixing member [3] steady when loosening the shaft of the
ITB joint shaft [2]. (Unless the drum fixing member is held down, the shaft
is not loosened and rotates with the drum.)
2. Check to see that the fixing member of the connection shaft is removed
certainly.
(When the fixing member is removed, the connection shaft moves back to
front.)
3. Be sure to loosen the shaft fully since the processing unit cannot be
removed unless this shaft is fully loosened.
[1]
[2]
13) Remove the drum fixing member [1] while holding it to prevent its rota-
tion.
- 1 screw [2]
Pay attention when pulling out the drum fixing member [1].
[2]
14) Shift down the fixing/feeding release lever [1] in the direction of the ar-
row.
[3]
F-2-68
[1]
F-2-69
[1]
15) Pull out the fixing feed unit [1] to the full length.
16) Press the two claws [1] and pull out the fixing feed unit to the full length.
17) Pull out the process unit [1].
- In the case of pulling out process unit, check to see as instructed in the
step 10) that the connector [1] is completely disconnected.
- Check to see that the adjuster is locked in place.
Chapter 2
F-2-70
[1]
F-2-71
[1]
[1]
F-2-72
2-37