Power Supply; Overview; Protection Function - Canon imageRUNNER iR2270 Service Manual

Hide thumbs Also See for imageRUNNER iR2270:
Table of Contents

Advertisement

Chapter 2
 

2.7 Power Supply

2.7.1 Overview

Upon being turned on, the host machine supplies 24 VDC and 13 VDC to the finisher
controller PCB immediately. 24 VDC is used to drive motors. 13 VDC is converted to 5 V
by the DC-DC converter in the finisher controller PCB to be used to drive sensors and ICs.
13V
5V
24V
24V
F-2-26

2.7.2 Protection Function

24 VDC lines connected to motors are provided with fuses for overcurrent protection.
The 24 DVC line connected to the host machine is provided with a fuse (FU1) and the 13
VDC line connected to the logic circuit is also provided with a fuse (FU2) for overcurrent
protection.
2-26
5V
5R
FET
3.3V
CW/CCW
PWM
CW/CCW
PWM
A/B
lref
A/B
lref
A/B
lref
0006-1979
M1
M2
M3
M4
M5
0006-1980