Canon imagePRESS C1 P Service Manual page 1007

Imagepress c1 series
Table of Contents

Advertisement

Chapter 16
Subheading
ADJ-Y/M/C/K
OFST-Y/M/C/K
LD-OFS-Y/M/C/K
MD-OFS-Y/M/C/K
HD-OFS-Y/M/C/K
10. HV-PRI
Subheading
PRIMARY
GRID
HVRATE-3
11. HV-TR
Subheading
PRE-TR
2TR-TGT1 to 8
16-110
COPIER > ADJUST > COLOR
Adjust the color balance for users. (Y/M/C/K color)
Adjustment method
- When you set a larger value, the image density becomes darker.
- When you set a smaller value, the image density becomes lighter.
Adjustment range: -8 to +8
[Factory setting value / Value after RAM clear: 0]
Adjust the density and color balance of a bright section. (Y/M/C/K color)
Adjustment method
- When you set a smaller value, fogging is reduced.
Adjustment range: -32 to +32
[Factory setting value / Value after RAM clear: 0]
Adjust the color balance of low-density area. (Y/M/C/K color)
Adjustment range: -8 to +8
[Factory setting value / Value after RAM clear: 0]
Use of this mode must be avoided as much as possible when the machine has been operating
normally.
Adjust the color balance of middle-density area. (Y/M/C/K color)
Adjustment range: -8 to +8
[Factory setting value / Value after RAM clear: 0]
Use of this mode must be avoided as much as possible when the machine has been operating
normally.
Adjust the color balance of high-density area. (Y/M/C/K color)
Adjustment range: -8 to +8
[Factory setting value / Value after RAM clear: 0]
Use of this mode must be avoided as much as possible when the machine has been operating
normally.
COPIER > ADJUST > HV-PRI
Adjust the current of the primary charging assembly.
Adjustment range: 0 to 1200 (Unit: µA)
[Factory setting value / Value after RAM clear: 1000]
Adjust the grid bias of the primary charging assembly.
Setting range: 0 to 1000 (Unit: 1V)
[Factory setting value / Value after RAM clear: 464]
Adjust the parameter setting ratio of the primary charging bias / laser power. (Feeding speed: 1/3
speed)
Adjustment method
Adjust the parameter setting ratio of the primary charging bias / laser power at the feeding speed
of 1/3 speed.
Setting range: 0 to 100 (This can be set in the unit of 1.)
[Factory setting value / Value after RAM clear: 100]
COPIER > ADJUST > HV-TR
Set a current value of the pre-transfer charging assembly. (common to Y/M/C/K)
Adjustment range: -120 to 0 (Unit: 5.0 uA)
[Factory setting value / Value after RAM clear: 0]
Set an offset value for the target current value of the secondary transfer ATVC.
Adjustment method
When the product's operation mode matches the setting of TR-ENV, TR-PPR, TR-CLR, and TR-
DUP, the target current value of the secondary transfer ATVC is offset according to the setting
value of this mode.
Adjustment value: -10 to 10 (Unit: 2uA)
[Factory setting value / Value after RAM clear: 0]
Reference:
6 items of 2TR-TGT, 2TR-SHR, TR-PPR, TR-ENV, TR-CLR, and TR-DUP are treated as one
set.
T-16-111
Contents
T-16-112
Contents
T-16-113
Contents
Level
1
1
2
2
2
Level
1
1
2
Level
1
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagepress c1Imagepress c7000 series

Table of Contents