Canon imagePRESS C1 P Service Manual page 1088

Imagepress c1 series
Table of Contents

Advertisement

Subheading
FREG-SW
Switching over of display/nondisplay for free register area of MEAP counter (for SEND)
settings
0: do not display (default); 1: display
MEMO:
- This is not used at normal servicing because it is for trouble analysis.
- Obey the instruction by the quality support section for usage.
IFAX-SZL
Set validity/invalidity of the transmission size restriction for iFAX transmission. (only when
transmission is not performed via a server)
settings
0: set restrictions; 1: do not set restrictions (only if not through server; default)
In the case of setting '0',
- as for upper limit value, set it in transmission data size by selecting the following:
additional functions mode>System Settings>Communications Settings>E-mail/I-Fax
Settings>Maximum Data Size For Setting
- if sending data that the size exceeds the upper limit value, it will be #830 error.
IFAX-PGD
Set whether or not to permit a split transmission by page. (only when the upper limit of the
transmission data size is exceeded)
This mode is used to switch "permission/non-permission" of a split transmission by page when
the upper limit of the transmission data size is exceeded in the iFAX Simple mode.
Setting range
0: Do not permit a split transmission by page.
1: Permit a split transmission by page.
Standard value
0
The split transmission by page does not assure the order of pages at the receiver. In addition, it
may be possible that any other reception job steps between the pages.
When setting this mode, explain the foregoing possibility to the user and gain the consent
beforehand.
MEAPSAFE
Make a setting to switch to the MEAP safe mode.
Setting range
0: Normal mode
1: Safe mode
Standard value
0
Safe mode works to stop the added MEAP application, and to startup the only system application
that was activated at initial state to start up the system safely.
Set '1' to startup in safe mode in the case of system recovery processing when MEAP platform
does not startup normally because of resource competition among MEAP applications, or the
order to register/use the service.
"MPSF" is indicated in the control panel screen when in safe mode.
FXEX-CNT
Set a temperature control hysteresis width for the external heating roller.
The external heating roller of this machine has small heat capacity and the heater is frequently
turned on and off, which causes a flickering. This mode is provided as a measure to minimize such
flickering.
Evaluation method
Make sure that the temperature of the external heating roller is controlled within the setting range
using COPIER>DISPLAY>ANALOG>FIX-EXC.
Setting range
0: Hysteresis width = ±1 deg C (200 deg C ±1 deg C)
1: Hysteresis width = ±2 deg C (200 deg C ±2 deg C)
2: Hysteresis width = ±3.5 deg C (200 deg C ±3.5 deg C)
3: Hysteresis width = ±4.5 deg C (200 deg C ±4.5 deg C)
Standard value
0
COPIER>OPTION>USER
Contents
Chapter 16
Level
2
2
2
2
2
16-191

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagepress c1Imagepress c7000 series

Table of Contents