- The fixing belt is pressed by the fixing roller.
- The fixing roller and the fixing belt are driven by the fixing motor (M38).
Stand-by
- The fixing belt is separated from the fixing roller.
- The fixing motor (M38) is stopped. The fixing belt is driven by the fixing belt drive motor (M36).
Error code :
E014 (Fixing motor error)
0001 Indicates that after the stable rotation of the fixing motor, the phase-lock signal of the fixing motor is not detected for 1 sec or more.
0002 Indicates that after the stable rotation of the fixing belt motor, the phase-lock signal of the fixing belt motor is not detected for 1 sec or more.