Chapter 15: Maintaining Your Library
Using Sift Sort
680
From the drop-down list to the right of the Partition drop-
down list, select All, Good, Suspect, Bad, or Untested.
c To use an additional filter, in the Media Filter field, type the
search string and click Filter.
For example, to filter all media containing the character 8, type
*8*.This field is case sensitive.
The appropriate media appears in the Select SSE Media section
below.
4 Optionally, in the Barcode File Selection section, you can filter
using a file using a "user-supplied" file (that lists barcodes).
a Click Browse to locate the appropriate file.
b Clicking Enable File Filter tells the interface to filter out
barcodes contained in that file.
If the barcodes in that file do not belong to the particular
partition selected, those barcodes are highlighted in red in the
Select SSE Media section and are not selectable.
5 Once you have selected media to sift sort, in the SSE Starting Slot
Destination area, click Explorer to select a coordinate location
graphically by clicking on a cell.
6 To relocate a cartridge to the last empty slot of the destination
element selected, ensure Relocate Full check box is checked.
Note: The Relocate Full box is checked as the default condition.
When Relocate Full is checked, any tapes in the destination area
will be moved to the lowest available element address location in
the partition.
When Relocate Full is not checked, tapes that exist in the
destination area will not be moved (skipped).
7 Click OK. The Control Module screen appears.
Quantum Scalar i6000 User's Guide