Chapter 15: Maintaining Your Library
Maintenance Actions
638
Boundary/Accessibility
The Boundary/Accessibility graphical report shows the results for tests of
the accessor while performing Get, Put, and Scan functions for all tape
magazines and drive sleds. (This tests whether magazines and sleds are
within the maximum allowable movement range of the accessor.)
• If the graphical report shows a failed result for one or more tape
magazines, make sure the magazines at the location of the failure
are installed properly and that the calibration targets are correctly
snapped on to the magazines.
• If the graphical report shows a failed result for the I/E station, make
sure the I/E station and front door are completely shut.
• If running the test again still generates failed results, realign the
middle X-axis rail and check the alignment of the top and bottom X-
axis rails at the location of the failure.
See
Figure 73
on page 639.