Quantum Scalar i6000 User Manual page 669

Tape library
Hide thumbs Also See for Scalar i6000:
Table of Contents

Advertisement

Quantum Scalar i6000 User's Guide
Note: Make sure that your scratch tapes are formatted and
contain no data that cannot be overwritten. Scratch tapes
must have barcode labels with valid volume serial (volser)
numbers on them. Also, you might find it useful to write
down the volser number so that you can identify your
scratch tapes.
This procedure will not damage any cartridges that are
already installed in the library.
If the scratch cartridge becomes lodged in a drive or
magazine, it must be manually removed from the library. If
not removed, the cartridge will become part of the
partition the next time the accessor assembly is enabled.
The I/E station will be locked until the inventory is complete.
10 Select a scratch cartridge of each media type listed on the following
dialog box.
Note: You can select one scratch cartridge per media type. Each
test that requires a scratch cartridge will call the media
types as needed.
Chapter 15: Maintaining Your Library
Maintenance Actions
651

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sci6000

Table of Contents