Configuring Host Access to Storage Networking Drives and Partitions
10 Click Next to display the Select the drives for host access dialog
box.
11 To add drives to the host access group, select their check boxes in
the Select column.
Caution: If control path failover is configured for a partition you
are planning to add to this host access group, make
sure you assign both the control path drive and the
control path failover drive to this host access group. If
you do not, then if the control path fails over, you will
lose host access to the partition.
12 For each drive selected, make sure to select either Port 1 or Port 2
for processing drive commands (the default is Port 1). Both drive
ports are active and have different WWPNs, so the port you choose
must be physically connected to a host or switch or the host will not
see it. Exception: If the drive is configured for Data Path Failover,
you should only select Port 1(if the data path fails over to Port 2, the
host will still be able to access it because DPF is configured).