Quantum Scalar i6000 User Manual page 647

Tape library
Hide thumbs Also See for Scalar i6000:
Table of Contents

Advertisement

Table 50 Test Results
Test Results
PASSED
FAILED
INCOMPLETE
SKIPPED
WARNING
STOPPED
Quantum Scalar i6000 User's Guide
Blade Inventory
This inventory list provides the following information about each Fibre
Channel I/O blade:
• Location of each blade
• Serial number
• Firmware version
Test Results
The results of all subtests appear on the Verification Tests dialog box
after each individual test is completed. See
of test results.
Explanation
Completed the test without reported errors.
An error has been found and needs to be corrected. A fatal error, or an error that
causes a part of the system to become disabled, will halt the test.
This portion of a test was incomplete due to an interruption or a portion of the
test was run (for example, no scratch tape was used so must only use existing
tapes). An incomplete will occur when the door is opened, an abort command is
issued, or when the Robotics Enable button is pressed.
This portion of the test was skipped. The cause is that either a scratch tape was
not present or the library was not configured for the test.
A warning is additional information about the test that the user should know.
For example, if a calibration failed, but the stored offsets are analyzed, a warning
should be posted that states that the offset check might not be accurate.
The test was interrupted. The log will show the result to provide a record of test
interruption.
Note: A single problem in the library can cause failed results in
multiple tests. After taking action to correct a failed result, run
tests that yielded failed results again.
Chapter 15: Maintaining Your Library
Maintenance Actions
Table 50
for an explanation