Chapter 3: Configuring Your Library
Configuring Control Paths
160
control path and control path failover, see
page 361 instead.
1 Log on as an administrator.
2 Access the appropriate screen in one of two ways:
• Select Setup > Partitions > Control Path from the main
console.
• Select Setup > Drives > Access > SNW Wizard. Click Next.
From the Select Storage Networking Option screen, select
Control Path and click Next.
The Storage Networking Partitions dialog box appears,
displaying all partitions that contain drives eligible to for control
path bridging (HP LTO-5 or later drives connected to an Ethernet
Expansion blade).
3 Click to highlight the row containing the partition whose control
path settings you want to configure.
4 Click OK. The Control Path dialog box appears.
Configure Control Path
Quantum Scalar i6000 User's Guide