Test Descriptions
This section describes the verification tests and their associated
tests
that are available.
Note: Refer to
Sub-test Descriptions
each sub-test.
Install Test
The Install Test enables you to verify that the library's installation and
configuration is complete and functioning correctly. The Install Test
automatically runs the following individual sub-tests:
• Library alignment test
• Picker assembly test
• I/E station assembly test
• Get/Put test
• Scanner fiducial test
Smaller library configuration requires about 1 hour and the larger
configurations require as long as 6 hours to run the Install Test. Partial
Test
The Partial Test performs the selected sub-tests to test an area or range
of the library configuration. The available sub-tests include:
• Frame test - This test includes the same individual tests as the Install
Test, but enables you to specify a range of modules rather than
testing all modules.
• Configuration test - This test includes the picker assembly and
scanner fiducial tests.
Both tests enable you to select a range of modules and racks to test. For
example, if you have a four-module library, you can select to test only
modules 3 and 4. The Frame test performs the same operations as the
installation verification test, except there are frame and rack range
parameters available.
FRU Test
The FRU test enables you to verify the replacement of a FRU. When the
FRU test is selected, you can select any of the following sub-tests:
Chapter 15: Maintaining Your Library