Quantum Scalar i6000 User Manual page 694

Tape library
Hide thumbs Also See for Scalar i6000:
Table of Contents

Advertisement

Chapter 15: Maintaining Your Library
Maintenance Actions
676
5 Verify that the I/E station in each partition has at least one free slot,
and then click Yes. A dialog box appears notifying you that all
partitions must be taken offline before defragmenting can begin.
6 Click Yes to take all partitions offline.
The partitions defragmentation operation starts. A progress bar at
the top of the Partitions Defragmentation dialog box displays the
percentage complete for the operation.
When defragmenting is complete, a dialog box appears prompting
you to take all partitions online.
7 Click Yes to take all partitions online.
8 Click Close to close the Partitions Defragmentation dialog box.
Canceling Defragmentation
Depending on the size of the library, defragmenting partitions can be a
time-consuming process. If needed, you can click Abort on the
Partitions Defragmentation dialog box to cancel the defragmentation
operation at any time. When prompted, click Yes to confirm the action.
After you cancel defragmentation, the library finishes moving the
current magazine (and any media it contains), then defragmentation
stops. If you cancel defragmentation, no tapes will be stranded, and all
media will still be assigned to the correct partition. You can resume
defragmentation at a later time by clicking Start on the Partitions
Defragmentation dialog box.
Recovering After Defragmentation is Interrupted
If a defragmentation operation fails (for example, if a power
interruption occurs or the robotics go offline), no tapes will be stranded,
and all media will still be assigned to the correct partition. However, it is
possible that some media which was in the process of being moved will
remain in the I/E station.
In this case, simply import the media into the library. The media will
automatically be moved to a magazine in the correct partition. For more
information about importing media, see
Partitions
on page 697.