Chapter 3: Configuring Your Library
Setting Up the Network Configuration
172
1 From the local operator panel only, select Setup > Network
Configuration > Internal IP. The Change Internal IP dialog box
appears.
By default, the internal IP subnet address that is automatically
selected on the Change Internal IP dialog box is not the one to
which your internal network is currently set. For example, the
current internal network IP setting is 192.19.x.x,. The drop-down
menu has multiple subnet options from 192.19.x.x to 10.90.x.x.
2 To accept the automatic internal IP setting, click OK. The following
warning message appears.
Caution: Setting the internal IP network to be on the same
subnet that the external IP network is on causes library
failure and results in the management interface (the
MCB) becoming unusable. For example, if you set
10.10.X.X as the internal IP network and your external
IP network is also 10.10.X.X, a conflict occurs. If you
are unsure about whether the change is appropriate,
select No.
3 If you are sure that you want to make the change, select Yes.
4 After the library processes the request successfully, a message
appears that asks you whether you want to shut down the library.
You must shut down and restart the library in order for the changes
to take effect.
Quantum Scalar i6000 User's Guide