11-3 Alarms

Emergency Stop Operation at Alarms

The emergency stop function controls the motor and stop it immediately, if an alarm that
supports for emergency stop occurs.
Related Parameters
Parameter
number
Pn510
Pn511
Pn513
Pn614
Pn615
11
11-13
Parameter name
Stop Selection for
Set the states during deceleration and after stop, when
Alarm Detection
an alarm occurs.
Emergency Stop
Set the torque limit for emergency stops.
Torque
Overspeed Detection
If the motor rotation speed exceeds the set value, the
Level Setting
Overspeed (Alarm No.26.0) occurs.
Alarm Detection
Set the allowable time required until the motor stops by
Allowable Time Setting
an emergency stop due to an alarm.
Overspeed Detection
If the motor speed exceeds the set value during an
Level Setting at
emergency stop due to an alarm, the Overspeed 2
Emergency Stop
(Alarm No.26.1) occurs.
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Explanation
Reference
P.8-46
P.8-47
P.8-47
P.8-54
P.8-54