Pn211
Notch 4 Width Setting
Setting
0 to 20
range
Select the notch width of resonance suppression notch filter 4.
Increasing the setting value widens the notch width. Normally, use the default set value.
While the adaptive filter is enabled, it is set automatically.
Refer to "10-6 Adaptive Filter (P.10-25)" and "10-7 Notch Filter (P.10-28)".
Pn212
Notch 4 Depth Setting
Setting
0 to 99
range
Set the notch depth of resonance suppression notch filter 4.
Increasing the setting value shortens the notch depth and the phase lag.
While the adaptive filter is enabled, it is set automatically.
Refer to "10-6 Adaptive Filter (P.10-25)" and "10-7 Notch Filter (P.10-28)".
Pn213
Damping Filter Selection
Setting
0 to 3
range
Set the method to switch among four damping control filters.
Explanation of Set Values
Set
value
0
Damping filter 1 or 2 enabled
1
Reserved for manufacturer use
2
Reserved for manufacturer use
It is switched with position command direction.
3
• Forward direction: Damping filters 1 / 3 enabled
• Reverse direction: Damping filters 2 / 4 enabled
*1 The set value 1 and 2 are for manufacturer's use only. Users are not allowed to set 1 and 2 for this
parameter.
Pn214
Damping Frequency 1
Setting
0 to 2000
range
Set damping frequency 1 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
The range of setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9
Hz.
Refer to "10-5 Damping Control (P.10-21)".
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
8-3 Vibration Suppression Parameters
Unit
Unit
Unit
Explanation
*1
*1
Unit
0.1 Hz
Default
Data
2
setting
attribute
Default
Data
0
setting
attribute
Position Full closing
Default
Data
0
setting
attribute
Position Full closing
Default
Data
0
setting
attribute
All
B
All
B
B
8
B
8-22