Pn801
Soft Limit
Setting range
0 to 3
Select whether to enable or disable the Soft Limit.
When it is enabled, set the soft limit values on the Forward Software Limit (Pn804) and the Reverse
Software Limit (Pn806).
Explanation of Set Value
Set value
0
Enable the soft limits on both directions.
1
Disable the forward soft limit, but enable the reverse soft limit.
2
Enable the forward soft limit, but disable the reverse soft limit.
3
Disable the soft limits on both directions.
Precautions for Correct Use
The disabled limit signals turn to enable (or in the state of set value 0), during the
MECHATROLINK-II communications status or if the origin return is not completed.
Pn802
Unused
Setting range
Pn803
Origin Range
Setting range
0 to 250
Set the threshold for detecting the origin in absolute values.
Pn804
Forward Software Limit
1073741823 to
Setting range
1073741823
Set the forward software limit.
Pn805
Unused
Setting range
Pn806
Reverse Software Limit
1073741823 to
Setting range
1073741823
Set the reverse software limit.
Pn807
Unused
Setting range
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Unit
Default setting
Description
Unit
Default setting
Unit
Default setting
Command
Unit
Default setting
unit
Unit
Default setting
Command
Unit
Default setting
unit
Unit
Default setting
8-7 Special Parameters
All
0
Data Attribute
All
Data Attribute
All
0
Data Attribute
All
500000
Data Attribute
All
Data Attribute
All
500000
Data Attribute
All
Data Attribute
8-62
A
8
A
A
A