5-4 Full Closing Control
External Feedback Pulse Error Setting (Pn328, Pn329)
The difference between the encoder position and external encoder position is detected, and if
the difference exceeds the value of Internal/External Feedback Pulse Error Counter Overflow
Level (Pn328), an error occurs.
Parameter
number
Pn329: Internal/External Feedback Pulse Error Counter Reset
5
Every time the motor rotates for the amount set by Pn329, the internal/external feedback pulse
error is cleared.
This function can be used when there is deviation between the position calculated from
encoder pulses and the position calculated from external encoder due to slipping, etc, and
internal/external feedback pulse errors accumulate.
Amount of internal/external feedback pulse error
[command unit]
 An internal/external feedback pulse error counter overflow level error occurs when the external
encoder is abnormal, connection is wrong, or connection point between the motor and load is
loose, among others. Accordingly, check these items when an error occurs.
 Be sure to set an appropriate value for Internal/External Feedback Pulse Error Counter Reset
(Pn329). If an extremely small value is set, this function may not operate.
 Use with extra caution on safety by installing limit sensors, etc.
5-15
Parameter name
Internal/External
Feedback Pulse
Pn328
Error Counter
Overflow Level
Internal/External
Feedback Pulse
Pn329
Error Counter
Reset
Pn328 Internal/External Feedback Pulse Error Counter Overflow Level
Pn329
Internal/External Feedback
Pulse Error Counter Reset
Precautions for Correct Use
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Explanation
Set the allowable difference (hybrid error)
between the encoder-detected position
and external encoder-detected position
in the command unit.
The hybrid error becomes 0 every time
the motor rotates by the set value. If the
set value is 0, the hybrid error is not
cleared.
Error detection
0 clear
Pn329
Pn329
Internal/External Feedback
Internal/External Feedback
Pulse Error Counter Reset
Pulse Error Counter Reset
Setting
range
27
1 to 2
0 to 100
0 clear
Number of motor
rotations [rotation]
Unit
Command
unit
Rotation