Omron OMNUC G5 R88M-K series User Manual page 196

Ac servomotors/servo drives with built-in mechatrolink-ii communications
Hide thumbs Also See for OMNUC G5 R88M-K series:
Table of Contents

Advertisement

4-3 Wiring Conforming to EMC Directives
Circuit Diagram
SUP-EK5-ER-6
R
Cx
3SUP-HU30-ER-6
4
IN
R
Noise Filter for the Brake Power Supply
 Use the following noise filter for the brake power supply.
Note. Noise can also be reduced by 1.5 turns with the ZCAT3035-1330 (TDK) Radio Noise Filter.
4-31
L
L
Cy
Cx
Cy
L1
Cx1
Cx1
Cy1
Rated
Model
current
SUP-EK5-ER-6
5 A
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
3SUP-HQ10-ER-6
IN
R
3SUP-HL50-ER-6B
LINE
OUT
Rated
Leakage current
voltage
250 V
1.0 mA (at 250 Vrms, 60 Hz)
OUT
L1
Cx1
Cx1
Cy1
LOAD
Manufacturer
Okaya Electric
Industries Co., Ltd.

Hide quick links: