4-4 Regenerative Energy Absorption
Regenerative Energy Absorption with an External Regeneration Resistor
If the regenerative energy exceeds the regeneration absorption capacity of the drive, connect
an External Regeneration Resistor.
Connect the External Regeneration Resistor between B1 and B2 terminals on the drive.
Double-check the terminal names when connecting the resistor because the drive may be
damaged if connected to the wrong terminals.
The External Regeneration Resistor will heat up to approx. 120C. Do not place it near
equipment and wiring that is easily affected by heat. Attach radiator plates suitable for the heat
radiation conditions.
External Regeneration Resistor
Characteristics
4
R88A-
RR08050S
R88A-
RR080100S
R88A-
RR22047S
R88A-
RR50020S
4-43
Resistance
Nominal
Model
value
capacity
50
80 W
100
80 W
47
220 W
20
500 W
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
The amount of
Heat
regeneration
radiation
absorption for 120C
condition
temperature rise
Aluminum
250 250,
20 W
Thickness: 3.0
Aluminum
250 250,
20 W
Thickness: 3.0
Aluminum
350 350,
70 W
Thickness: 3.0
Aluminum
600 600,
180 W
Thickness: 3.0
Thermal switch output
specifications
Operating temperature
150C 5% NC contact
Rated output: 30 VDC,
50 mA max.
Operating temperature
150C 5% NC contact
Rated output: 30 VDC,
50 mA max.
Operating temperature:
170 7C
NC contact
Rated output: 250 VAC,
0.2 A max.
Operating temperature
200 7C
NC contact
Rated output: 250 VAC,
0.2 A max.
24 VDC, 0.2 A max.