Pn614
Alarm Detection Allowable Time Setting
Setting
0 to 1000
range
Set the allowable time required until the motor stops by an emergency stop due to an alarm.
When he time exceeds the set value, the operation forcibly turns to an alarming state.
When the parameter is set to 0, the protection by allowable time does not function.
Refer to the Emergency Stop Operation at Alarms in "11-3 Alarms (P.11-6)".
Pn615
Overspeed Detection Level Setting at
Setting
0 to 20000
range
If the motor speed exceeds the set value during an emergency stop due to an alarm, the
Overspeed 2 (Alarm No.26.1) occurs.
The overspeed detection level setting is 1.2 times the maximum motor rotation speed if this
parameter is set to 0.
This parameter should normally be set to 0. The setting should be changed only when it is
necessary to lower the overspeed detection level.
Refer to "Emergency Stop Operation at Alarms" (P.11-13) in "11-3 Alarms (P.11-6)".
Pn616
Unused
Setting
range
Pn617
Unused
Setting
range
Pn618
Power Supply ON Initialization Time
Setting
0 to 100
range
Set initialization time after power supply ON to the standard 1.5 seconds plus some.
Refer to the Control Output Sequence in "3-1 Servo Drive Specifications (P.3-1)" for the details at power
on.
Pn619
Unused
Setting
range
Pn620
Unused
Setting
range
Pn621
Unused
Setting
range
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Unit
ms
Emergency
Stop
Unit
r/min
Unit
Unit
Unit
0.1 s
Unit
Unit
Unit
8-7 Special Parameters
Default
Data
200
setting
attribute
Default
Data
0
setting
attribute
Default
Data
setting
attribute
Default
Data
setting
attribute
Default
Data
0
setting
attribute
Default
Data
setting
attribute
Default
Data
setting
attribute
Default
Data
setting
attribute
All
B
All
A
All
All
8
All
R
All
All
All
8-54