Pn522
No. 2 Torque Limit
Setting
0 to 500
range
Set the limit value for the output torque (Pn013: No. 1 Torque Limit, Pn522: No. 2 Torque Limit) of the motor.
Refer to information on the Torque Limit Selection (Pn521) to select the torque limits.
During torque control, maximum torques for both forward and reverse directions are limited.
Settings in Torque Limit Selection (Pn521) and No. 2 Torque Limit (Pn522) is ignored.
Make the settings as a percentage of the rated torque.
[Example] Maximum torque is limited to 150%
When Pn013 or Pn522 = 150
Refer to "5-3 Torque Control (P.5-6)" for more information on torque limits and the torque limit selection.
Pn523
Unused
Setting
range
Pn524
Unused
Setting
range
Pn525
Forward External Torque Limit
Setting
0 to 500
range
Set the forward external torque limit upon torque limit switching input.
Pn526
Reverse External Torque Limit
Setting
0 to 500
range
Set the reverse external torque limit upon torque limit switching input.
Pn527
Unused
Setting
range
Pn528
Unused
Setting
range
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Unit
%
Torque [%]
Forward
300 (maximum)
200
100 (rated)
100
(rated)
200
300
Reverse
Unit
Unit
Unit
%
Unit
%
Unit
Unit
8-6 Extended Parameters
Position Speed Full closing
Default
Data
0
setting
attribute
Speed
(maximum)
Default
Data
setting
attribute
Default
Data
setting
attribute
Position Speed Full closing
Default
Data
0
setting
attribute
Position Speed Full closing
Default
Data
0
setting
attribute
Default
Data
setting
attribute
Default
Data
setting
attribute
B
All
8
All
B
B
All
All
8-50