Omron OMNUC G5 R88M-K series User Manual page 176

Ac servomotors/servo drives with built-in mechatrolink-ii communications
Hide thumbs Also See for OMNUC G5 R88M-K series:
Table of Contents

Advertisement

4-2 Wiring
R88D-KN06F-ML2/-KN10F-ML2/-KN15F-ML2/-KN20F-ML2
4
1MC
2MC
Noise filter (*1)
Ground to 100 Ω
or less
Regeneration
Resistor
24 VDC
User-side
control
device
Control cables
4-11
R
S
T
3-phase 380 to 480 VAC 50/60Hz
NFB
Main circuit power supply
OFF
X
OMNUC G5-Series
AC Servo Drive
CNC
24 V
0 V
24 VDC
1
2
3
NF
E
4
5
6
CNA
L1
L2
L3
CND
B1
(*4)
B3
B2
CN1
X
3
/ALM
4
ALMCOM
X
CN1
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Main circuit contactor (*1)
ON
1MC
2MC
Surge suppressor (*1)
1MC
2MC
X
Servo alarm display
XB
CNB
24 VDC
U
V
W
Ground to 100 Ω
or less
CN2
Encoder cables
CN1
OUTM1
24 VDC
XB
1
(BKIR)
(*2)
OUTM1
2
COM
2MC
1MC
PL
OMNUC G5-Series
AC Servomotor
Power cables
(*3)
*1. A recommended product is listed in 4-3,
Wiring Confirming to EMC Directives.
*2. Recommended relay: MY relay by
OMRON (24-V type) For example, MY2
relay by OMRON can be used with all
G5-series motors with brakes because its
rated induction load is 2 A (24 VDC).
*3. There is no polarity on the brakes.
*4. The Regeneration Resistor buit-in type
(KN06F-ML2 to KN15F-ML2) connects
B2 and B3. When the amount of
regeneration is large, connect the
necessary Regeneration Resistor
between B1 and B2.
B
M
E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnuc g5 r88d-kn series

Table of Contents