Automated Attendant Did Assignment - NEC Xen IPK Programming Manual

Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

December 2004
Automated Attendant DID
Assignment
General Description
Use this Memory Block to determine the action after a DID call arrives at an extension or CAR,
and is not answered after predetermined time.
Display
Tel Port
No.
Data
(01~99)
No.
A0~C0
0 1 / 5 8 : D I D
T I M E
Settings
LK 1
LK 2
NON
AA1
LK 5
LK 6
AA4
AA5
Page 2
LK 9
LK 10
AA8
LK 13
LK 14
Programming Procedures
Go off-line.
1
Press LK4 +
to access the Memory Block.
2
EH
3
Press corresponding CO/PBX line key to change setting data 1.
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
R
to move to the next Tel Port No
For example, to assign AA6, press LK7 to display.
N
4
Press
to write the data and display the next line key.
5
Repeat example and step 4 until all line key assignments are complete, and press
P
6
Press
to go back on-line.
Related Programming
M.B. Number
1-4-02
Automated Attendant Transfer Delayed Ringing Time Selection
DRAFT 3
464 – Chapter 1
Setting
Title
Data
N O N / 1
D I S P L A Y
LK 3
LK 4
AA2
AA3
LK 7
LK 8
AA6
AA7
The shaded area indicates
the default setting.
LK 11
LK 12
LK 15
LK 16
Page
No.
Memory Block Name

Automated Attendant DID Assignment, 4-58

NEC Business Solutions Ltd
4-58
System Mode
Submode
Data No.
PC Programming
Default Values
NON
N
to enter last data
4
58
+ AU
.

Advertisement

Table of Contents
loading