Pc Programming Password Assignment - NEC Xen IPK Programming Manual

Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

December 2004
PC Programming Password
Assignment
General Description
Use this Memory Block to assign system passwords that must be entered when connecting to
the system using MAT PC Programming.
Display
Data
Class
No.
No. 1
1 7 :
( 1 ) =
T I M E
Programming Procedures
1
Go off-line.
2
Press LK1 + LK8 +
AG
Use the following to enter Class 1(Technician Mode) and password (8 digits max).
3
Note:
Use the following to enter data:
K~I
to enter numeric data
U
Press
N
Press
to write the data and advance to Class 2 (End User Mode).
4
5
After entering Class 2 password, press
6
Program the next Memory Block or press
Related Programming
No related programming is necessary for this Memory Block.
N
1. Password 1 (Class 1) is used for Technician MAT PC Programming
2. Password 2 (Class 2) is used for End User MAT PC Programming.
3. Password 1 (Class 1) can be assigned only by telephone programming. It cannot be assigned or changed by
Technician or End User MAT PC Programming.
4. Password 2 (Class 2) can be assigned by telephone programming or Technician MAT PC Programming. It cannot be
assigned or changed by End User MAT PC Programming.
5. Password 2 (Class 2) cannot be assigned until password 1 (Class 1) is assigned in the Memory Block.
6. For passwords for both classes; only the first 5 digits are used.
DRAFT 3
238 – Chapter 1
Setting
Data
D I S P L A Y
to access the Memory Block.
to clear data
N
P
to write the data. The next Memory Block is displayed.
to go back on-line.

PC Programming Password Assignment, 1-8-17

NEC Business Solutions Ltd
1-8-17
System Mode
1
Submode
8
Data No.
17
PC Programming
+ CSP
Default Values
Class 1, 2 All Blank

Advertisement

Table of Contents
loading

Table of Contents