Xen IPK
PBR Interdigit Release Timer
Selection
General Description
Use this Memory Block to specify the interdigit release time for the Push Button Receiver (PBR).
Display
Data
No.
1 0 : P B R
T I M E
Settings
LK 1
LK 2
3 sec.
4 sec.
LK 5
LK 6
7 sec.
8 sec.
Programming Procedures
1
Go off-line.
2
Press LK1 + LK8 +
AK
Press the corresponding CO/PBX line key to change the data option.
3
N
4
Press
to write the data.
P
5
Press
to go back on-line.
Related Programming
M.B. Number
1-3-03
First Digit PBR Release Timer Selection
1-8-01
SLT or Automated Attendant/DISA to PBR Selection
N
A DTMF Single Line Telephone connected to the Xen system must be supported by a PBR that receives DTMF signals.
1-8-10, PBR Interdigit Release Timer Selection
Setting
Data
Title
R E L E A S
7 s
D I S P L A Y
LK 3
LK 4
5 sec.
6 sec.
LK 7
LK 8
9 sec.
10 sec.
to access the Memory Block.
The shaded area indicates
the default setting.
Memory Block Name
Programming Manual
1-8-10
System Mode
1
Submode
8
Data No.
10
PC Programming
+ BM
DRAFT 3
Chapter 1 – 229