Hold Recall Time Selection
(Exclusive)
General Description
Use this Memory Block to specify the time for Exclusive Hold Recall. If No Limit is selected,
Exclusive Hold Recall is not provided.
With IPK R2000 and above, this memory block allows flexible entries and has four classes.
For R2000 only.
Display
Data
No.
6 3 : H O L D
T I M E
Settings
LK 1
LK 2
0.5 min.
1 min.
LK 5
LK 6
3 min.
5 min.
Programming Procedures
1
Go off-line.
Press LK1 + LK1 +
2
FC
3
Press the corresponding CO/PBX line key to change the data option.
N
4
Press
to write the data.
P
5
Press
to go back on-line.
For R2000 and above.
Display
Data
No.
6 3 : H O L D R C L
T I M E
Programming Procedures
1
Go off-line.
Press LK1 + LK1 +
2
FC

1-1-63, Hold Recall Time Selection (Exclusive)

Setting
Title
Data
R E C L
1 . 0
D I S P L A Y
LK 3
LK 4
1.5 min.
2 min.
The shaded area indicates
the default setting.
LK 7
LK 8
8 min.
No Limit
to access the Memory Block.
Setting
Title
Class
Data
X = 0 6 0 s
D I S P L A Y
to access the Memory Block.
Programming Manual
1-1-63
System Mode
1
Submode
1
Data No.
63