NEC Xen IPK Programming Manual page 97

Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

Xen IPK
N
1. Select options from the list of function numbers in Memory Block 1-1-46 Access Code (1-Digit) Assignment, and
assign a number (from 0~9), , or # to each selected function.
When a function is assigned a 1-digit Access Code, 2-digit Access Codes with the same first digit become invalid
(i.e., if a function is assigned to Access Code 5, Access Codes 50~59, 5 , and 5# cannot be used.)
2. To enter # or
3. This Memory Block is used when a 2- or 3-Digit Station Numbering Plan is programmed.
4. LCR must always use trunk group 1 Access Code.
5. When 4 digit extension numbering plan is used dial numbers 1~8 should be assigned as 000 (not used).
Assignment of extension number range is done in Memory Block 1-1-47, e.g. 1-1-46:
0 = 080 1~8 = 000
9 = 176
* = 095
# = 096
4 digit extension range required is 4000~4100
Memory Block 1-1-47
40 = 001 and 41 = 001.
It is then possible to use Memory Block 4-10 Station Number Assignment.
6. Call Forward Off Premise uses the same access codes as Internal Call Forward, however a Trunk Access Code is
entered instead of an Extension.
1-1-46, Access Code (1-Digit) Assignment
as part of an Access Code, press
Q
then
L
or
J
.
Programming Manual
DRAFT 3
Chapter 1 – 77

Advertisement

Table of Contents
loading

Table of Contents