Tie Line Incoming Interdigit Timeout Selection - NEC Xen IPK Programming Manual

Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

Xen IPK
Tie Line Incoming Interdigit
Timeout Selection
General Description
Use this Memory Block to specify a time interval during the incoming call detection process so
that if an address signal is not received within a specified time, an error tone is returned to the
other system.
Display
CO/PBX
No.
Data
(01~64)
No.
0 1 / 2 4 :
T I M E
(Page 1)
LK 1
LK 2
No Limit
1 sec.
LK 5
LK 6
4 sec.
5 sec.
(Page 2)
LK 1
LK 2
8 sec.
9 sec.
LK 5
LK 6
12 sec.
13 sec.
Programming Procedures
1
Go off-line.
N
2
Press LK3 +
+
3
Press the corresponding CO/PBX line key to change the data option.
Note:
Use the following enter data:
S
to go to the next page
T
to go to the previous page
R
to go to the next CO/PBX Line No.
N
4
Press
to write the data.
P
5
Press
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.

3-24, Tie Line Incoming Interdigit Timeout Selection

Setting
Page
Title
Data
No.
I N C O M
6 s
| 1
D I S P L A Y
LK 3
2 sec.
3 sec.
LK 7
6 sec.
7 sec.
LK 3
10 sec.
11 sec.
LK 7
14 sec.
15 sec.
BD
to access the Memory Block.
LK 4
LK 8
The shaded area indicates
the default setting.
LK 4
LK 8
Programming Manual
System Mode
3
Submode
Data No.
24
PC Programming
+ ALM
DRAFT 3
Chapter 1 – 363
3-24

Advertisement

Table of Contents
loading