Hg-Link-Bundle-Monitor Rate-Interval - Dell Z9500 Reference Manual

Hide thumbs Also See for Z9500:
Table of Contents

Advertisement

Parameters
sfm npu-id hg-
port-channel
hg-port-
channel-id
slot slot-id
npuUnit npu-id
hg-port-
channel 0
enable
Command
CONFIGURATION
Mode
Command
Version
History
9.2(1.0)
9.3.0.0
Usage
You can configure HiGig link bundle monitoring so that a system log message or
Information
an SNMP trap is generated when traffic distribution in a bundle is uneven. The
formula that determines uneven traffic distribution is predefined.

hg-link-bundle-monitor rate-interval

Specify the interval (in seconds) for polling traffic distribution in the member links of a HiGig link bundle.
Z9500
Syntax
hg-link-bundle-monitor rate-interval seconds
To restore the default value, use the no version of this command.
Parameters
seconds
Command
CONFIGURATION
Mode
Command
Version
History
9.2(1.0)
9.3.0.0
Defaults
The default polling interval for HiGig link bundles is 15 seconds.
874
Specify a HiGig port channel on a Z9500 SFM (spine) NPU by
entering the keyword sfm and SFM NPU ID, then hg-port-
channel and a HiGig port channel ID. SFM NPU IDs are 0 to
5; SFM HiGig port-channel IDs are 0 to 10.
Specify a HiGig port channel on a Z9500 line-card (leaf) NPU
by entering the keyword slot and slot number, then
npuUnit and line-card NPU ID, then hg-port-channel 0.
Line-card slot numbers are 0 to 2; line-card NPU IDs are 0 to
3. The HiGig port-channel ID is always 0 because there is
only one HiGig link bundle on a line-card NPU.
Enable HiGig link-bundle monitoring.
Description
Introduced on the Z9500 switch.
Introduced on the Z9000 switch.
Polling interval in seconds. The valid values are from 10 to
299.
Description
Introduced on the Z9500 switch.
Introduced on the Z9000 switch.
Interfaces