Initial Network Setup Of Totalstorage Ds300 And Ds400 - IBM TotalStorage DS300 Best Practices Manual

Table of Contents

Advertisement

256 color video mode
On client station systems, the ServeRAID Manager is supported on a broad
range of operating systems, such as Windows, Linux, NetWare, UnixWare and
OpenServer.
Note: When installing the ServeRAID Manager on client stations, refer to the
OS-specific Readme.txt files on the ServeRAID Manager Application CD for a
list of supported operating systems and other operating system specific
information.
4.4 Initial network setup of TotalStorage DS300 and
DS400
This section explains the setup of the network addresses of the TotalStorage
DS300 and DS400 using the command line interface. IP address setup for the
management interface cannot be performed using the IBM ServeRAID Manager.
The TotalStorage DS300 and DS400 are shipped with default IP addresses.
Table 4-4 contains the default addresses for the management network ports of a
TotalStorage DS300 and DS400. The iSCSI ports of the DS300 do not have IP
addresses configured.
Note: Please note the slightly unusual network mask.
Table 4-4 TotalStorage DS300 and DS400 management port default network addresses
Controller
Controller A - Management port
Controller B - Management port
Note: When installing
BladeCenters, be sure not to run the unconfigured products at the same time.
IP address conflicts will occur.
The link speed of the management ports can be set for every controller using the
ServeRAID Manager. Global settings such as default gateway, DNS server,
domain and host name can be set for the enclosure using the ServeRAID
Manager.
Address
192.168.70.123/255.255.0.0
192.168.70.124/255.255.0.0
multiple
TotalStorage DS300, DS400 or IBM
Chapter 4. TotalStorage DS300 and DS400 management
75