9. When the firmware was successfully flashed and a alternate controller is
available, repeat the previous steps with controller B.
10.Verify the new boot image with boot info. The second image was overwritten
with the newer firmware version 6.21. The next boot image was set to 2.
DS300-1[A]# image info
----[ System firmware images ]---------------------------------------------
Next boot image: [2] [IBM TotalStorage DS Series (Build 0750)]
DS300-1[A]#
Figure 4-170 Command line interface — boot image information
11.Enter system reboot to reboot the TotalStorage DS300 or DS400. Both
controllers will reboot. The flashed firmware image will be used for booting
after this reboot.
DS300-1[A]# system reboot
Reboot the system? [No]: yes
The system is about to reboot
Figure 4-171 Command line interface — Reboot TotalStorage DS300 or DS400
The next section explains how to perform the same firmware update wit the IBM
ServeRAID Manager console.

4.12.2 Update DS300 and DS400 firmware with ServeRAID Manager

With ServeRAID Manager, multiple enclosures can be updated at the same time.
This is a new feature introduced with the ServeRAID Manager 8.20 the first time.
Image [1]: [IBM TotalStorage DS Series (Build 0750)]
[27/07/2005][6.21]
Image [2]: [IBM TotalStorage DS Series (Build 0750)]
[27/07/2005][6.21]
Current image: [1] [IBM TotalStorage DS Series (Build 0750)]
Chapter 4. TotalStorage DS300 and DS400 management
185