IBM TotalStorage DS300 Best Practices Manual page 562

Hide thumbs Also See for TotalStorage DS300:
Table of Contents

Advertisement

DS400[A]# initiator manage WOLGA-SLOT4-(1) info
----[ Initiators ]---------------------------------------------------------
----[ Initiator 'WOLGA-SLOT4-(1)' ]----------------------------------------
---------------------------------------------------------------------------
---------------------------------------------------------------------------
DS400[A]#
Figure 9-141 Verify all ports are disabled
4. Enable the ports by entering the command initiator manage
WOLGA-SLOT4-(1) allow all. This will activate the ports for this initiator. The
port access will be set to yes. Verify this with the command entered in step 3
on page 482.
DS400[A]# initiator manage WOLGA-SLOT4-(1) allow all
Access allowed to initiator WOLGA-SLOT4-(1) on all ports
DS400[A]#
Figure 9-142 Enable all ports
5. The other initiator WOLGA-SLOT3-(0) of the system WOLGA had one port enabled
to install the operating system onto a logical drive from a TotalStorage DS400.
The remaining three ports must be enabled as well. Check the ports with
initiator manage WOLGA-SLOT3-(0) info.
544
IBM TotalStorage DS300 and DS400 Best Practices Guide
WWN: 210000e08b0f1549
Alias: WOLGA-SLOT4-(1)
ID: 1
Port access:
Port A0
NO
LUN Mappings:
LUN
0
1
2
3
4
Port A1
Port B0
NO
NO
logical
[Capacity]
WOLGA-BOOT
[ 30.00GB]
WOLGA-DB
[ 15.00GB]
WOLGA-LOG
[ 11.01GB]
WOLGA-MEDIA
[100.00GB]
WOLGA-TEMP
[900.00MB]
Port B1
NO

Advertisement

Table of Contents
loading

This manual is also suitable for:

Totalstorage ds400

Table of Contents