Copier > Display > Cst-Sts - Canon iR3245 Series Service Manual

Hide thumbs Also See for iR3245 Series:
Table of Contents

Advertisement

COPIER > DISPLAY > ANALOG
Item
Level
TEMP
1
HUM
1
ABS-HUM
1
DR-TEMP
1
FIX-C
1
FIX-E
1
17.2.1.4 COPIER > DISPLAY > CST-STS
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
Description
Title
Machine temperature (environment sensor)
Purpose
Check the temperature inside the machine.
Note
-
Displays, settings and
-
adjustment ranges
Unit
Deg C
Appropriate guideline
Guaranteed environment for main body: temperature 15 deg C to 27.5 deg C, humidity 25% to 75%
Related service modes
-
Additional description and
Temperature/humidity detected by the environment sensor (left) is not used for the parameter of
notes
control.
Title
Machine humidity (environment sensor)
Purpose
Check the humidity inside the machine.
Note
-
Displays, settings and
-
adjustment ranges
Unit
%RH
Appropriate guideline
Guaranteed environment for main body: temperature 15 deg C to 27.5 deg C, humidity 25% to 75%
Related service modes
-
Additional description and
Temperature/humidity detected by the environment sensor (left) is not used for the parameter of
notes
control.
Title
Moisture amount (environment sensor)
Purpose
Check the amount of moisture.
Note
-
Displays, settings and
XX.xx
adjustment ranges
Unit
g
Appropriate guideline
0 to 20
Related service modes
-
Additional description and
-
notes
Title
Display of the temperature around the photosensitive drum
Purpose
To check if a fault in image is attributed to the temperature of the photosensitive drum.
Note
If the temperature is not within the standard range (approx 42.5 deg C), change the switch for heater
temperature setting or check the heater function.
Displays, settings and
-
adjustment ranges
Unit
Deg C
Appropriate guideline
Room temperature -/+ alpha (alpha; rise in temperature inside the machine)
Related service modes
-
Additional description and
-
notes
Title
Display of the temperature of the surface of fixing film unit (detected temperature by main thermistor)
Purpose
Check the temperature of the surface of fixing roller (detected temperature by main thermistor)
Note
-
Displays, settings and
-
adjustment ranges
Unit
Deg C
Appropriate guideline
Room temperature to 240 deg C. Approx. 240 deg C during executing a job.
Related service modes
-
Additional description and
-
notes
Title
Display of the temperature of the surface of fixing film unit (detected temperature by sub thermistor)
Purpose
Check the temperature of the surface of fixing roller (detected temperature by sub thermistor)
Note
-
Displays, settings and
-
adjustment ranges
Unit
Deg C
Appropriate guideline
Room temperature to 240 deg C. Approx. 240 deg C during executing a job.
Related service modes
-
Additional description and
-
notes
T-17-3
Chapter 17
0019-9274
17-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3225 series3230 series3235 series

Table of Contents