Canon iR3245 Series Service Manual page 578

Hide thumbs Also See for iR3245 Series:
Table of Contents

Advertisement

Chapter 17
Item
Level
CARD
1
E-RDS
1
RGW-PORT
1
COM-TEST
1
17-80
COPIER > FUNCTION > INSTALL
Description
Title
Setting of the card number of the card reader
Purpose
When installing the card reader/after replacing the HDD
Note
At execution, the card management information (department ID and personal identification number)
is initialized.
Displays, settings and
0 to 2001
adjustment ranges
Unit
-
Value at RAM clear
0
Setting/Adjustment/Operation
1) Select (highlight) the item.
method
2) Input the number of card to use and press the OK key.
3) Turn off/on the main power switch.
OK/NG criteria
-
Time required
-
Related service modes
COPIER > OPTION > BODY > CARD-RNG (level 2)
Additional description and
Serial number from the input to the number of cards set in CARD-RNG is the usable card number.
notes
Title
Setting to switch Embedded-RDS function use/unused
Purpose
At using Embedded-RDS
Note
Be sure to use the following five items; E-RDS, RGW-PORT, COM-TEST, COM-LOG, RGW-ADR
in a set.
Displays, settings and
0: Unused 1: Use (transmitting all counter information)
adjustment ranges
Unit
0
Value at RAM clear
-
Setting/Adjustment/Operation
1) Select (highlight) the item, input the setting, and then press the OK key.
method
2) Turn off/on the main power switch.
OK/NG criteria
-
Time required
-
Related service modes
COPIER > FUNCTION > INSTALL > E-RDS, RGW-PORT, COM-TEST, COM-LOG, RGW-
ADR(level 1)
Additional description and
Embedded-RDS is a function of transmitting device information such as device counter/fault/durables
notes
and consumables to the server of the sales company using SOAP protocol.
Title
Specifying the port number of the server of the sales company to be used in Embedded-RDS
Purpose
At using Embedded-RDS
Note
Be sure to use the following five items; E-RDS, RGW-PORT, COM-TEST, COM-LOG, RGW-ADR
in a set.
Displays, settings and
1 to 65535
adjustment ranges
Unit
443
Value at RAM clear
-
Setting/Adjustment/Operation
1) Select (highlight) the item, input the setting and press the OK key.
method
2) Turn off/on the main power switch.
OK/NG criteria
-
Time required
-
Related service modes
COPIER > FUNCTION > INSTALL > E-RDS, RGW-PORT, COM-TEST, COM-LOG, RGW-ADR
(level 1)
Additional description and
-
notes
Title
Checking the connection with the server of the sales company to be used in Embedded-RDS
Purpose
When using Embedded-RDS (Try to connect the server of a sales company, judge if the connection is
successful, and then display the result.)
Note
Be sure to set the following five items; E-RDS, RGW-PORT, COM-TEST, COM-LOG, RGW-ADR
in a set.
Displays, settings and
During operations: 'ACTIVE'
adjustment ranges
At connection: 'OK' When connection fails: 'NG'
Unit
-
Setting/Adjustment/Operation
Select (highlight) the item and press the OK key.
method
OK/NG criteria
It is OK if the display is changed into 'OK' after 'ACTIVE' (blinking) is displayed.
Time required
-
Related service modes
COPIER > FUNCTION > INSTALL > E-RDS, RGW-PORT, COM-TEST, COM-LOG, RGW-
ADR(level 1)
Additional description and
-
notes