Copier > Adjust > Pascal; Copier > Adjust > Hv-Pri - Canon iR3245 Series Service Manual

Hide thumbs Also See for iR3245 Series:
Table of Contents

Advertisement

Item
Level
BLANK-B
1
17.4.1.8 COPIER > ADJUST > PASCAL
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
Item
Level
OFST-P-K
1
17.4.1.9 COPIER > ADJUST > HV-PRI
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
Item
Level
OFST1-DC
1
COPIER > ADJUST > BLANK
Description
Title
Adjustment value entry for non-image width (trail edge)
Purpose
Enter the value on service label when executing RAM clear of DC controller PCB/replacing the PCB
Note
Note the value on service label when changing the setting value
Settings/Adjustment range
-128 to 127
Unit
-
Amount of change per unit
0.1 mm
Value at RAM clear/
0/Yes
adjustment at factory
shipment
Setting/Adjustment/Operation
1) Select the item to be highlighted to enter the setting value (switch with +/- key), and then press OK
method
key.
2) Turn OFF and then ON the main power switch.
- Increasing the value makes non-image width bigger.
Relevant Service Mode
-
Supplementary info/Memo
-
COPIER > ADJUST > PASCAL
Description
Title
Density adjustment at test print scanning
Purpose
Only when replacing reader controller PCB/executing Rcon clear
Note
Note the value on reader service label when changing the setting value
Settings/Adjustment range
-128 to +128
Unit
-
Amount of change per unit
-
Value at RAM clear/
0/Yes
adjustment at factory
shipment
Setting/Adjustment/Operation
1) Select the item to be highlighted to enter the setting value (switch with +/- key), and then press OK
method
key.
2) Turn OFF and then ON the main power switch.
Relevant Service Mode
-
Supplementary info/Memo
Execute offset adjustment for test print scanning signal in PASCAL control at auto gradation
correction (full correction)
COPIER > ADJUST > HV-PRI
Description
Title
Adjustment value entry for primary charging DC offset 1
Purpose
When executing RAM clear of DC controller PCB/replacing the PCB
When replacing power supply PCB
Note
Enter the value on the label attached to the case of the new power supply PCB when replacing the
power supply PCB.
Settings/Adjustment range
-128 to 127
Unit
-
Amount of change per unit
-
Value at RAM clear/
0/No
adjustment at factory
shipment
Setting/Adjustment/Operation
1) Select the item to be highlighted to enter the setting value (switch with +/- key), and then press OK
method
key.
2) Turn OFF and then ON the main power switch.
Relevant Service Mode
-
Supplementary info/Memo
-
T-17-23
T-17-24
Chapter 17
0019-9285
0019-9286
17-59