m. Press [OK].
n. Press [OK].
o. Press [Close].
p. Press the Reset key to quit the Additional Functions.
q. Turn the device OFF/ ON.
(4) e-Maintenance/imageWARE Remote settings
a. Select Service mode>COPIER>Function>Clear>ERDS-DAT, and then press [OK].
b. Select Service mode>COPIER>Function>INSTALL>E-RDS, enter [1] and press [OK]. This turns ON the function that enables communication with UGW.
c. Select Service mode>COPIER>Function>INSTALL>COM-TEST and press [OK]. This initiates the communication test between the device and UGW. If the
communication is successful, OK is displayed. If NG (FAIL) appears, refer to the troubleshooting guide and repeat until OK is displayed.
F-12-5
F-12-6
F-12-7
Chapter 12
12-3