Chapter 7
7.3.3 Sequence of Operation (last rotation)
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
The sequence of operation of last rotation is as follows:
Main motor
(M-motor)
Primary charging
(PRI)
Laser
(LD)
Developing AC
(DEV_AC)
Developing DC
(DEV_DC)
Developing clutch
(DEV_CL)
Transfer
(TR)
Static removal
(SEP)
In [1] above, a cleaning bias (-2600 V) is applied.
7-6
Image write
end
F-7-7
[1]
0018-9703