Chapter 17
Item
Level
OFST1-AC
1
17.4.1.10 COPIER > ADJUST > HV-TR
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
Item
Level
TR-OFST
1
TR-SPP
1
17-60
COPIER > ADJUST > HV-PRI
Description
Title
Adjustment value entry for primary charging AC offset 1
Purpose
When executing RAM clear of DC controller PCB/replacing the PCB
When replacing the power supply PCB.
Note
Enter the value on the label attached to the case of the new power supply PCB when replacing the
power supply PCB.
Settings/Adjustment range
-128 to 127
Unit
-
Amount of change per unit
-
Value at RAM clear/
0/No
adjustment at factory
shipment
Setting/Adjustment/Operation
1) Select the item to be highlighted to enter the setting value (switch with +/- key), and then press OK
method
key.
2) Turn OFF and then ON the main power switch.
Relevant Service Mode
-
Supplementary info/Memo
-
COPIER > ADJUST > HV-TR
Description
Title
Offset output adjustment value entry for transfer charging current
Purpose
When executing RAM clear of DC controller PCB/replacing the PCB
Note
Enter the value on service label
Settings/Adjustment range
-128 to 127
Unit
-
Amount of change per unit
-
Value at RAM clear/
0/No
adjustment at factory
shipment
Setting/Adjustment/
1) Select the item to be highlighted to enter the setting value (switch with +/- key), and then press OK
Operation method
key.
2) Turn OFF and then ON the main power switch.
Relevant Service Mode
-
Supplementary info/Memo
-
Title
Output adjustment value entry for transfer bias with thick paper (at 1-sided print with thick paper, at
the 1st side print of 2-sided print with thick paper)
Purpose
When executing RAM clear of DC controller PCB/replacing the PCB
Note
Enter the value on service label.
Increasing the value makes the bigger impact.
Settings/Adjustment range
-128 to 127
Unit
-
Amount of change per unit
-
Value at RAM clear/
0/No
adjustment at factory
shipment
Setting/Adjustment/
1) Select the item to be highlighted to enter the setting value (switch with +/- key), and then press OK
Operation method
key.
2) Turn OFF and then ON the main power switch.
Relevant Service Mode
-
Supplementary info/Memo
-
T-17-25