The value which has been set takes effect after the main power switch has been turned OFF and back ON.
Item
Level
Description
MEAP-DSP
2
Title
Purpose of use, When used
Precautions for use
Settings and adjustment
ranges
Unit
Value at time of shipment
from factory/Value
established when RAM is
cleared
Setting, adjustment and
operation procedures
Related service modes
Additional description and
notes
ANIM-SW
2
Title
Purpose of use, When used
Precautions for use
Settings and adjustment
ranges
Unit
Value at time of shipment
from factory/Value
established when RAM is
cleared
Setting, adjustment and
operation procedures
Related service modes
Additional description and
notes
BASE-SW
1
Title
Purpose of use, When used
Precautions for use
Settings and adjustment
ranges
Unit
Value at time of shipment
from factory/Value
established when RAM is
cleared
Setting, adjustment and
operation procedures
Related service modes
Additional description and
notes
MEAP-SSL
2
Title
Purpose of use, When used
Precautions for use
Settings and adjustment
ranges
Unit
Value at time of shipment
from factory/Value
established when RAM is
cleared
Setting, adjustment and
operation procedures
Related service modes
Additional description and
notes
COPIER > OPTION > BODY
Setting to prohibit screen display switching from MEAP screen to standard screen
Prohibit the switching of the screen display from the MEAP screen to the standard screen (COPY/
SEND/BOX screen, etc.).
-
0: Switching enabled (the display can transfer to the standard screen)
1: Switching disabled (the display cannot transfer to the standard screen)
-
0
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
-
Even when '1' is set, the display will transfer to the standard screen when an error, jam or alarm has
occurred.
Setting to prohibit switching of display to error or jam screen while the MEAP application is running
Prohibit the switching of the display to the error or jam screen while the MEAP application is running
-
0: Switching enabled (the warning screen is displayed)
1: Switching disabled (the warning screen is not displayed)
-
0
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
COPIER > OPTION > BODY > MEAP-DSP (Level 2)
Even when COPIER > OPTION > BODY > MEAP-DSP is set to '1', the display will transfer to the
standard screen to display the warning screen if an error, jam or alarm has occurred. When this item is
set to '1' and then an error, jam and alarm has occurred:
- Screen transfer to the standard screen will be prohibited.
- A warning display urging the user to contact the service engineer in charge appears on the MEAP
screen.
Switching from MEAP-Full model to Base model
This item is used when trouble caused by the MEAP application has occurred. Switch from the MEAP-
Full model to the Base model.
-
0: OFF (Base model)
1: ON (Full model)
Set to '0' when restricting to the operation of the MEAP application for the purposes of trouble
analysis.
-
1
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
-
The setting of this item can be changed only from '1' to '0'.
Setting of HTTPS port for MEAP
Set the port of the HTTPS server when SSL is used by HTTP of MEAP.
-
0 to 65535
-
8443
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
-
-