Chapter 17
Item
Level
FAN-CHK
1
FAN-ON
1
SL-CHK
1
SL-ON
1
17-100
Description
Title
Checking the ADF cooling fan
Purpose of use
-
Situation
-
Precautions for use
-
Displays, settings and
0: Cooling fan
adjustment ranges
Unit
-
Value at RAM clear
-
Setting/Adjustment/Operation
1) Press FAN-CHK (to highlight).
method
2) Input the number of an appropriate part with keypad.
3) Press the OK key.
4) Press FAN-ON to check the operation.
OK/NG criteria
-
Time required
-
Related service modes
FEEDER > FUNCTION > FAN-ON (level 1)
Additional description and
-
notes
Title
Starting the fan operation
Purpose of use
-
Situation
-
Precautions for use
-
Displays, settings and
-
adjustment ranges
Unit
-
Value at RAM clear
-
Setting/Adjustment/Operation
1) Press FAN-ON and the OK key to start the fan operation.
method
2) Press the OK key again to stop the operation. (It automatically stops in approx. 5 sec, however
'STOP' is not displayed unless pressing the OK key again.)
OK/NG criteria
-
Time required
-
Related service modes
FEEDER > FUNCTION > FAN-CHK (level 1)
Additional description and
-
notes
Title
Checking the ADF solenoid
Purpose of use
-
Situation
-
Precautions for use
-
Displays, settings and
0: Pressure solenoid
adjustment ranges
1: Stamp solenoid
Unit
-
Value at RAM clear
0
Setting/Adjustment/Operation
1) Press SL-CHK (to highlight).
method
2) Input the number of an appropriate part with keypad.
3) Press the OK key.
4) Press SL-ON and check the operation.
OK/NG criteria
-
Time required
-
Related service modes
FEEDER > FUNCTION > SL-ON (level 1)
Additional description and
-
notes
Title
Starting the solenoid operation
Purpose of use
-
Situation
-
Precautions for use
-
Displays, settings and
-
adjustment ranges
Unit
-
Value at RAM clear
-
Setting/Adjustment/Operation
The operation specification varies according to the model.
method
1) Press SL (to highlight) and the OK key to start the motor operation.
2) Press the OK key again to stop the operation. (It automatically stops in approx. 5 sec, however
'STOP' is not displayed unless pressing the OK key again.)
OK/NG criteria
-
Time required
-
Related service modes
FEEDER > FUNCTION > SL-CHK (level 1)
Additional description and
-
notes
FEEDER > FUNCTION