Canon iR3245 Series Service Manual page 626

Hide thumbs Also See for iR3245 Series:
Table of Contents

Advertisement

Chapter 17
The value which has been set takes effect after the main power switch has been turned OFF and back ON.
Item
Level
BOX-BKUP
1
RAG-CONT
1
DNSTRANS
1
MIBCOUNT
2
17-128
COPIER > OPTION > BODY
Description
Title
Switch to permit restoration of BOX backup data
Purpose of use, When used
This item is used for replacement. Permit restoration of the backup data of other models (some
models).
Precautions for use
-
Settings and adjustment
0: Restoration is permitted when the target model is the same model.
ranges
1: Restoration is permitted when the target model is a one-generation succeeding model.
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
The setting value returns to '0' when restoration has been successfully completed.
notes
Title
Setting of the level of fixing smear control mode
Purpose of use, When used
Set the level of fixing smear control mode.
Precautions for use
-
Settings and adjustment
0 to 3
ranges
Unit
-
Value at time of shipment
2
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
Title
DNS transfer priority switch
Purpose of use, When used
If both IPv6 and IPv4 are used and the DNS server supports IPv4, timeout occurs when DNS query is
executed by giving priority on IPv6. This item is used to give priority on DNS query by IPv4 in a case
like this. Determine the priority level on the protocol to be used for DNS query (IPv4/IPv6) based on
the value of DNStrans.
Precautions for use
-
Settings and adjustment
0: IPv4 1: IPv6
ranges
Unit
-
Value at time of shipment
1
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
Title
Charge counter MIB switch
Purpose of use, When used
This item is used not to display the charge counter MIB. Change the range of the charge counter MIB
scope.
Precautions for use
-
Settings and adjustment
0: All charge counter MIBs are displayed.
ranges
1: All charge counter MIBs displayed on the LUI are displayed.
2: No charge counter MIBs are displayed.
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3225 series3230 series3235 series

Table of Contents