Chapter 17
The value which has been set takes effect after the main power switch has been turned OFF and back ON.
Item
Level
MODEL-SZ
1
FIX-CLN
2
FIX-TEMP
1
CPMKP-SW
2
17-102
COPIER > OPTION > BODY
Description
Title
Selection of standard variable size display and ADF document detection size
Purpose of use, When used
Select the standard variable size display and ADF document detection size.
Precautions for use
-
Settings and adjustment
0: AB type (6R5E)
ranges
1: Inch type (5R4E)
Unit
-
Value at time of shipment
Varies depending on the destination.
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
The value (0, 1) is automatically set in accordance with the destination.
notes
Title
Setting of the frequency to execute fixing cleaning
Purpose of use, When used
Set the frequency to execute fixing cleaning.
Precautions for use
-
Settings and adjustment
0: Do not execute cleaning
ranges
1: Once every 500 prints, temperature control at 225degC, idling for 60 sec
2: Once every 200 prints, temperature control at 225degC, idling for 60 sec
3: Once every 100 prints, temperature control at 225degC, idling for 60 sec
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
Title
Selection of the fixing temperature mode
Purpose of use, When used
Select the fixing temperature mode.
Precautions for use
-
Settings and adjustment
0: OFF
ranges
1: Priority is given to productivity. The controlled temperature is fixed at -20degC.
2: The controlled temperature is fixed at -10degC.
3: The controlled temperature is set to -20degC only when the room temperature is 21degC or higher.
4: The controlled temperature is set to -10degC only when the room temperature is 21degC or higher.
5: The controlled temperature is fixed at +6degC.
6: The controlled temperature is fixed at +10degC.
7: The controlled temperature is fixed at +15degC.
Unit
degC
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
COPIER > OPTION > BODY > TEMP-CON (Level 1)
COPIER > OPTION > BODY > TEMPCON2 (Level 1)
Additional description and
This item can be used with the setting of TEMP-CON or TEMPCON2.
notes
Example)
When "FIX-TEMP=-6degC, TEMP-CON=-6degC" is set, the controlled temperature is offset at -
12degC.
Title
ON/OFF of sequence to decrease the copy speed
Purpose of use, When used
Decrease the copy speed to maintain fixing performance.
Precautions for use
-
Settings and adjustment
0 : OFF 1 : ON
ranges
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
T-17-50