Chapter 17
Item
Level
RUI-RJT
2
CTM-S06
2
FREG-SW
2
IFAX-SZL
2
17-148
COPIER > OPTION > USER
Description
Title
Setting as to whether to disconnect HTTP port during illegal authentication from remote UI
Purpose of use, When used
Disconnect the HTTP port when illegal authentication has occurred 3 times from a remote UI.
Precautions for use
-
Settings and adjustment
0: The HTTP port is not disconnected.
ranges
1: The HTTP port is disconnected.
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
Title
Setting to delete password from the transmission address export file
Purpose of use, When used
This item is used when the leakage of information is to be prevented. Set the deletion of the password
from the file transmission address export file.
Precautions for use
-
Settings and adjustment
0: The password is not deleted.
ranges
1: The password is deleted.
When '1' is set, the password for the transmission destination is deleted from the export file when the
address book data is exported from the remote UI.
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
Title
Selection of whether to display MEAP counter (for SEND) free register area
Purpose of use, When used
This item is used when trouble is analyzed. Select whether to display the free register area of the
MEAP counter (for SEND).
Precautions for use
- This must not be used for regular servicing.
- It must be used in accordance with the instructions given by the Quality Support department.
Settings and adjustment
0: The free register area is not displayed.
ranges
1: The free register area is displayed.
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
The MEAP counter has a free register area in which the MEAP applications can be counted up
notes
independently.
Title
Selection of whether to impose transmission size limits during IFAX transmissions
Purpose of use, When used
Enable data whose volume is greater than the upper limit of the transmission data size to be transmitted
in IFAX transmissions which do not go through the server.
Precautions for use
-
Settings and adjustment
0: The transmission size limit is imposed (both when the transmissions go through and do not go
ranges
through the server).
1: The transmission size limit is released (but only when the transmissions do not go through the
server).
Error #830 results if data whose volume exceeds the upper limit is transmitted when '0' is set.
Unit
-
Value at time of shipment
1
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
The upper limit for the transmission data size can be set in the user mode by selecting the following:
notes
system control settings > communication control settings > I-FAX settings > upper limit of
transmission data size